CHA3028 Display Image
CHA3028 Display Image

Binder Stability Chamber KBFLQC720 700L

Code: CHA3028 N1-1

Benefits

  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast ...


    read more

    Your Price
    £31,596.00 EACH
    £37,915.20 inc. VAT

Benefits

  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Variable position and removable illumination cassettes
  • ICH-compliant illumination for long-term stable test conditions
  • Precise photometry with 3D ball-type sensors at the sample

Important characteristics

  • Temperature range: 0°C to +70°C
  • Temperature range with light: +10°C to +60°C
  • Humidity range: 10% to 80% RH
  • 3 positionable illumination cassettes with ICH-compliant UV/Vis light source
  • Independent light-dose control of UV-A and visible light with spherical sensors
  • APT.line™ preheating chamber technology
  • Humidity regulation with capacitive humidity sensor and vapor humidification
  • Inner chamber made of stainless steel
  • BINDER Multi Management Software APT-COM™ Basic Edition
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Unit self-test for comprehensive status analysis
  • Tight-sealing inner door made of safety glass (ESG) with special TIMELESS coating
  • 3 stainless steel racks
  • Access port with silicone plug, 30mm, left
  • 4 stable castors, two with brakes
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Door heating

KBFLQC720-230V
Performance Data Temperature
Max. heat compensation at 40°C with illumination, W1000
Temperature range with 100% illumination, °C10 to 60
Temperature range without illumination cassettes, °C0 to 70
Performance Data Climate
Humidity fluctuation with illumination at 25°C and 60% RH, ±% RH2
Humidity fluctuation with illumination at 40°C and 75% RH, ±% RH2
Humidity range with illumination cassettes, with illumination, % RH10 to 75
Humidity range without illumination, % RH10 to 80
Humidity recovery time after 30s door open at 25°C and 60% RH with illumination, min1
Humidity recovery time after 30s door open at 40°C and 75% RH with illumination, min5
Temperature fluctuation with illumination at 25°C and 60 % RH, ±K0.2
Temperature fluctuation with illumination at 40°C and 75% RH, ±K0.2
Temperature range with 100% illumination, °C20 to 60
Temperature range without illumination cassettes, °C10 to 70
Temperature variation with illumination at 25°C and 60% RH, ±K1.2
Temperature variation with illumination at 40°C and 75% RH, °K1.2
Lightdata per Illumination Cassettes
ICH compliant illumination for photo stability testing, lx*9000
ICH compliant illumination for photo stability testing, W/m2*1.5
Electrical data
Nominal power, kW3.5
Phase (Nominal voltage)1~
Power frequency, Hz50
Rated Voltage, V200 to 230
Unit fuse, A16
Doors
Inner doors2
Unit doors2
Housing dimensions not incl. fittings and connections
Depth net, mm890
Height net, mm1925
Width net, mm1250
Internal Dimensions
Depth, mm576
Height, mm1250
Width, mm973
Measures
Interior volume, L700
Load per rack, kg45
Net weight of the unit (empty), kg374
Permitted load, kg150
Wall clearance back, mm100
Wall clearance sidewise, mm200
Environment-specific data
Energy consumption at 40°C and 75% RH, Wh/h2350
Sound-pressure level, dB(A)53
Fixtures
Number of illumination cassettes (std./max.)3/3
Number of shelves (std./max.)3/12
This product has met the following criteria: